Loading...
ORD 987 08/23/2011 O F Cts g1111UUNx/IN,i \\a\11a �Hyi4 O r 0 „ * * 1Texas "City of Choice” INTERNATIONAL RESIDENTIAL CODE ORDINANCE NO. q S 7 AN ORDINANCE OF THE CITY OF CIBOLO AMENDING CHAPTER 14 OF THE CITY'S CODE OF ORDINANCES; ADOPTING THE 2009 EDITION OF THE INTERNATIONAL RESIDENTIAL CODE, REGULATING AND GOVERNING THE CONSTRUCTION, ALTERATION, MOVEMENT, ENLARGEMENT, REPLACEMENT, REPAIR, ERECTION, LOCATION, REMOVAL AND DEMOLITION OF DETACHED ONE AND TWO FAMILY DWELLINGS AND MULTIPLE SINGLE FAMILY DWELLINGS (TOWNHOUSES) NOT MORE THAN THREES STORIES IN HEIGHT WITH SEPARATE MEANS OF EGRESS IN THE CITY OF CIBOLO; PROVIDING FOR PENALTIES FOR THE VIOLATION OF THIS ORDINANCE; PROVIDING FOR THE ISSUANCE OF PERMITS AND COLLECTION OF FEES THEREFOR; REPEALING ALL ORDINANCES AND REGULATIONS IN CONFLICT AND THAT THIS ORDINANCE IS CUMULATIVE OF ALL OTHER ORDINANCES OF THE CITY NOT IN CONFLICT WITH THE PROVISIONS OF THIS ORDINANCE. WHEREAS,the City of Cibolo is a Home Rule Municipality located in Guadalupe County,Texas, created in accordance with provisions of the Texas Local Government Code and operating pursuant to its adopted City Charter and all applicable laws and enabling legislation of the State of Texas; and WHEREAS,the City of Cibolo is governed by a Home Rule Charter that was approved by the Citizens of Cibolo in a duly called election held on September 11,2004; and WHEREAS, Chapter 54.001 of the Texas Local Government Code provides the general authority for the City of Cibolo to enforce each rule, ordinance, or police regulation of the City of Cibolo and to punish a violation of a rule, ordinance, or police regulation; and WHEREAS, Chapter 214.212 of the Texas Local Government Code provides the general authority for the City of Cibolo to adopt local amendments to the International Residential Code; and WHEREAS,the City of Cibolo,Texas seeks to protect the health, safety, and welfare of the citizens of the City of Cibolo; and Page 1 of 7 WHEREAS,the City of Cibolo,Texas seeks to regulate and govern the construction, alteration,movement, enlargement, replacement, repair, erection, location, removal and demolition of detached one and two family dwellings and multiple single family dwellings (townhouses) not more than threes stories in height with separate means of egress, and from conditions hazardous to life or property in the occupancy of buildings and premises in the City of Cibolo. NOW THEREFORE THE CITY COUNCIL OF THE CITY OF CIBOLO DOES HEREBY AMEND THE CITY'S CODE OF ORDINANCES AS FOLLOWS: Section 1. Code Amendment That the Cibolo Code of Ordinances Section 14-2(a)(5)is hereby amended to read as follows: (1) That a certain document,three(3) copies of which are on file in the office of the Building Official of Cibolo, being marked and designated as the International Residential Code, 2009 edition, including Appendix Chapters A, B, C, D, E,F, G, H, I, J,K, M,N, 0, P, and Q, as published by the International Code Council, be and is hereby adopted as the Residential Code of the City of Cibolo,in the State of Texas for regulating and governing the construction, alteration,movement, enlargement, replacement, repair, erection, location, removal and demolition of detached one and two family dwellings and multiple single family dwellings (townhouses) not more than threes stories in height with separate means of egress as herein provided; providing for the issuance of permits and collection of fees therefor; and each and all of the regulations, provisions, penalties, conditions and terms of said Residential Code on file in the office of the Building Official of Cibolo, are hereby referred to, adopted, and made a part hereof, as if fully set out in this ordinance, with the additions, insertions, deletions and changes, if any, prescribed in (a), (b), (c), (d), (e), (f), (g), (h), (i)and(j)of this ordinance. (a) That the following sections and/or sub-sections are hereby revised to read as follows: R101.1 Title. These provisions shall be known as the Residential Code for One- and Two- Family Dwellings of Cibolo, and shall be cited as such and will be referred to herein as "this code". R102 Applicability is amended by adding section R102.8 to read as follows: R102.8 Plumbing, Gas, Sewer, Storm Drainage, Etc. All plumbing, gas, sewer, etc references and Chapters 24—33 are hereby deleted and replaced with the 2009 edition of the Uniform Plumbing Code(UPC). R105.2 Work exempt from permit is amended by deleting the following numbered exemption items listed under Building. Building:Numbers 1, 2 and 5 R105.3 Application for permit is amended by adding items 8, 9 and 10 to read as follows: 8. Indicate the total square footage, of the foundation and all floors above or below as measured from the exterior and indicate the number of stories. 9. Be accompanied by the International Energy Conservation Code compliance certification specific to the permitted address. Page 2 of 7 10. Indicate the total square footage of impervious cover ( i.e.: foundation, driveway, sidewalks etc). R106.1.1 Information on construction documents is amended by adding the following, which is not all inclusive: 1. Indicate the street name, address number, and lot and block numbers. 2. Engineered foundation plan.Foundation plans shall have all details identified. 3. Floor plans shall be scaled and laid out as it is to be built, if plans show optional details options shall be clearly indicated,show glazing percentages. 4. Frame details shall include but not be limited to live load design, wind speed design, wall bracing requirements, studs required for support of beams, header size and support requirements. 5. Roof and ceiling joist plan with specifications and details. 6. Electrical plan. 7. Plumbing plan. 8. Heating,ventilation,and air conditioning plan. 9. Construction plans shall have adopted codes listed. 10. Give such other data and information as required by the building official. 11. Indicate the total square footage of all impervious cover ( i.e.: foundation, driveway, sidewalks etc). R106.2 Site plan or plot plan is amended by adding the following which is not all inclusive: 1. Indicate the street name, address number, and lot and block numbers. 2. Provide total lot square footage. 3. Provide the total square footage of the foundation to include attached garages. 4. Indicate percentage of all impervious coverage. 5. Provide square footage of foundation to include garages, porches, patios, driveways, and walkways. 6. Indicate all building setback lines. 7. Indicate all easements. 8. Indicate property pin locations and distance. 9. Percentage of slope on driveway. 10. Indicate drainage elevation across the property. 11. Show curb lines and sidewalks. 12. Give such other data and information as required by the building official. R112.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the building official relative to the application and interpretation of this code, there shall be and is hereby created a board of appeals. The building official shall be an ex officio member of said board but shall have no vote on any matter before the board. The City Council may act as the board of appeals, or the board of appeals shall be appointed by the governing body and shall hold office at its pleasure. The board shall adopt rules of procedure for conducting its business, and shall render all decisions and findings in writing to the appellant with a duplicate copy to the building official. Page 3 of 7 Table R301.2(1)is amended by providing the local design criteria as follows: Table R301.2(1) Climatic and geographic design criteria. SEISMIC SUBJECT TO DAMAGE FROM GROUND WIND DESIGN DESIGN Frost WINTER ICE BARRIER FLOOD AIR MEAN SNOW CATEGORY line DESIGN UNDERLAYMENT HAZARDS FREEZING ANNUAL LOAD Mph effects f Weatheringa Depthb Termitec TEMPe REQUIREDh g INDEX1 TEMPS See 5 90 NO A Negligible 12" Moderate 30°F' No Adopted 50 days 70°F To Heavy Ordinance NOTES a thru k REMAIN AS WRITTEN R311.5 Construction is amended by adding section 12311.5.2 Obstruction to read as follows: R311.5.2 Obstruction.Except for a fence,no obstruction shall be placed in the side yard setback that impedes the ingress to or egress from the side yard area from front to back. There shall be a minimum clearance of 30 inches between any obstruction and the fence or property line. 12313.2 is amended to read as follows: 11313.2 One and two family dwellings automatic fire systems. As per Ordinance 778 approved and dated December 12, 2006, all one and two family dwellings 4500 square foot and larger shall have an automatic residential fire sprinkler system installed. The exception to remain as written. 402.2 Concrete is amended by adding section 402.2.1 Flatwork Specifications to read as follows: 402.2.1 Flatwork Specifications shall meet the requirements of the"Flatwork Requirements in the City of Cibolo"handout available at the permit office. R1006.3 Clearance. Unlisted combustion air ducts shall be installed with a minimum 2-inch (51 mm) clearance to combustibles for all parts of the duct within 5 feet (1524 mm) of the duct outlet. M1305.1 Appliance access for inspection service, repair and replacement. Appliances shall be accessible for inspection, service, repair and replacement without removing permanent construction, other appliances, or any other piping or ducts not connected to the appliance being inspected, serviced, repaired or replaced. A level working space at least 30 inches deep and 30 inches wide(762 mm by 762 mm) and not less than 3/4-inch (19 mm) thick shall be provided in front of the control side of the appliance. Installation of room heaters shall be permitted with at least an 18-inch (457 mm) working space. A platform shall not be required for room heaters. M1305.1.3 Appliances in attics. Attics containing appliances requiring access shall be provided with an opening with a permanent ladder and a-clear and unobstructed Page 4 of 7 passageway large enough to allow removal of the largest appliance, but not be less than 30 inches (762 mm) high and 22 inches (559 mm) wide and not more than 20 feet (6096 mm) in length measured along the centerline of the passageway from the opening to the appliance. The passageway shall have continuous solid flooring in accordance with Chapter 5 not less than 24 inches (610 mm) wide and not less than 3/4-inch (19 mm) thick. A level service space not less than 30 inches (762 mm) deep and 30 inches (762 mm) wide and not less than 3/4-inch(19 mm)thick shall be present along all sides of the appliance where access is required. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by 762 mm), where such dimensions are large enough to allow removal of the largest appliance. Exceptions to remain. M1501.1 Outdoor discharge. The air removed by every mechanical exhaust system shall be discharged to the outdoors. Air shall not be exhausted into an attic, soffit, ridge vent or crawl space. Exhaust ducts shall terminate not less than 3 feet(914 mm) in any direction from openings into buildings. M1502.3 Duct Termination. Exhaust ducts shall terminate on the outside of the building. Exhaust duct terminations shall be in accordance with the dryer manufacturer's installation instructions. If the manufacturer's instructions do not specify a termination location,the exhaust duct shall terminate not less than 3 feet(914 mm) in any direction from openings into buildings and not less than 3 feet(914 mm) from the condensor. Exhaust duct terminations shall be equipped with a back draft damper. Screens shall not be installed at the duct termination. (b) That all walls containing plumbing, piping, or conduit larger than 2 inch (38 mm) inside diameter shall have a minimum of 6 inch(152 mm) stud width. (c) That all references to the ICC Electrical Code are deleted and shall reference the current adopted version of the National Electric Code(NEC)NFPA 70. (d) That all pressure gauges installed or used for testing shall have the working range in the middle third of the gauges minimum and maximum pressure ends. (e) That all piping, ducting and similar penetrations through walls, floors and ceilings shall be sealed to prevent entry of rodents and insects. (f) That all water service and supply lines crossing under sidewalks or driveways shall be enclosed within a sleeve two pipe sizes greater than the pipe passing through, so as to allow removal and replacement, and shall be at a minimum depth of 12 inches (305 mm) below finish grade unless otherwise required by the code official. (g) The use of streets, alleys and public property for the storage or handling of materials or of equipment required for construction or demolition, and the protection provided to the public shall comply with the provisions of the authority having jurisdiction and this section. Page 5 of 7 (h) Construction materials and or equipment shall not be placed or stored so as to obstruct any street, alley, public right-of-way, access to fire hydrants, standpipes, fire or police alarm boxes, catch basins or manholes, nor shall such material or equipment be located within 20 feet (6.1 m) of a street intersection, or placed so as to obstruct normal observations of traffic signals or obstruct the view of traffic. (i) Construction materials, trash, garbage, rubbish, and debris shall be secured or contained in approved covered containers so as to prevent such items from leaving the property, lot or construction site. Uncovered containers may be approved in writing at the discretion of the code official. Construction sites shall be kept neat,clean and orderly and free of hazards. (j) Trenching and excavating. Underground utilities shall be located and marked before trenching or excavating. It shall be a violation of this ordinance to trench or excavate without properly making request for utility locates, and for damaging utilities that have been properly located. Requests shall be made using state recognized locating guidelines and procedures. Section 2. Cumulative. That this ordinance shall be cumulative of all provisions of the City of Cibolo, Texas, except where the provisions of this Ordinance are in direct conflict with the provisions of such Ordinances, in which event the more restrictive provision shall apply. Section 3. Severability That if any section, subsection, sentence, clause or phrase of this ordinance is, for any reason, held to be unconstitutional, such decision shall not affect the validity of the remaining portions of this ordinance. The City Council hereby declares that it would have passed this ordinance, and each section, subsection, clause or phrase thereof, irrespective of the fact that any one or more sections, subsections, sentences, clauses and phrases be declared unconstitutional. Section 4. Continuation of Existing Regulations. That nothing in this ordinance or in the Residential Code hereby adopted shall be construed to affect any suit or proceeding impending in any court, or any rights acquired, or liability incurred, or any cause or causes of action acquired or existing, under any act or ordinance hereby repealed as cited in Section 3 of this ordinance; nor shall any just or legal right or remedy of any character be lost, impaired or affected by this ordinance. Section 5. Effective Date. That this ordinance and the rules, regulations, provisions, requirements, orders and matters established and adopted hereby shall take effect and be in full force and effective upon the passage and approval of the City Council of the City of Cibolo, Texas and after having been published twice in the newspaper designated as the official newspaper of the City. Page 6 of 7 PASSED AND APPROVED on this the 23`d day of August,2011 APPROVED: Ilk 2AA.A1 kOA1 ' Je it fer H.; .n,Mayor ATTEST: //-.7 /-ey/y Peggy Cimics, City Secretary APPROVED AS TO FORM .:--. i,` City Attorney': Office n Page 7 of 7